Complete Optical, Colorimetric & Audiometric Screening Directory
Filter 92 calibrated screening plates, Snellen tiers, astigmatism checks, and frequency benchmarks.
1. Ishihara Plates & CVD Simulators (24 Tests)
Ishihara Plate #1 (Number 12) — Control Baseline Plate
Universal calibration plate readable by both normal vision and all forms of color vision deficiency.
Plate #2Ishihara Plate #2 (Number 8) — Red-Green Screening Plate
Tests primary L/M cone opponent contrast; red-green deficiency typically reads 3 or sees no digit.
Plate #3Ishihara Plate #3 (Number 29 vs 70) — Transformation Plate
Classic transformation design where normal trichromats read 29 and red-green deficiency shifts toward 70.
Plate #4Ishihara Plate #4 (Number 5) — Green-on-Warm Confusion Locus
Evaluates medium-wavelength green figure separation against warm terracotta luminance noise.
Plate #5Ishihara Plate #5 (Number 3 vs 5) — Chromatic Contour Check
Tests subtle curvature recognition along the deutan/protan confusion axis.
Plate #6Ishihara Plate #6 (Number 15) — Mid-Saturation Red-Green Plate
Moderate chromatic contrast sensitive to mild anomalous trichromacy.
Plate #7Ishihara Plate #7 (Number 74 vs 21) — High-Sensitivity Deutan Check
Renowned clinical benchmark plate: normal vision reads 74, while mild deuteranomaly often reads 21.
Plate #8Ishihara Plate #8 (Number 6) — Pure Vanishing Design
Pure vanishing plate with zero secondary confusion digit; disappears completely under dichromacy.
Plate #9Ishihara Plate #9 (Number 45) — Double-Digit Vanishing Check
Tests balanced central vision across two wide pseudo-isochromatic numerals.
Plate #10Ishihara Plate #10 (Number 7) — Sage-Green Vanishing Plate
Isolates green-cone response against warm ochre background dots.
Plate #11Ishihara Plate #11 (Number 16) — Coral-Sage Screening Plate
Confirms reproducibility of red-green chromatic detection.
Plate #12Ishihara Plate #12 (Number 73) — Fine Threshold Screening Plate
Narrower chromatic separation crafted to detect borderline deuteranomaly.
Plate #13Ishihara Plate #13 (Number 26) — Protan vs. Deutan Diagnostic Plate
Differential plate: Protanopia sees 6 clearly; Deuteranopia sees 2 clearly; Normal reads 26.
Plate #14Ishihara Plate #14 (Number 42) — Differential Protan/Deutan Confirmation
Second differential classification plate confirming L-cone vs M-cone sensitivity.
Plate #15Blue-Yellow Tritan Screening Plate #15 (Number 35)
Screens rare S-cone blue-yellow color deficiency along the tritanopic confusion line.
Plate #16Blue-Yellow S-Cone Plate #16 (Number 96) — Violet-Olive Axis
Tests short-wavelength violet discrimination against olive-green background.
Plate #13Protanopia (Red-Blindness) Interactive Test & Live Vision Simulator
Interactive L-cone deficiency simulator showing exactly how Protanopia transforms Ishihara plates.
Plate #7Deuteranopia & Deuteranomaly (Green Deficiency) Test & Simulator
Explore the most common form of inherited color blindness (~6% of males) with live M-cone simulation.
Plate #15Tritanopia (Blue-Yellow Color Blindness) Online Screening & Filter
Test S-cone blue-yellow perception and preview how tritanopia shifts blues and yellows toward teal/pink.
Plate #1Total Color Blindness (Monochromacy / Achromatopsia) Vision Preview
Demonstrates pure rod-luminance grayscale perception and why Control Plate #12 remains readable.
Plate #6Military, Police & Defense Academy Color Blindness Practice Check
Practice standard 16-plate pseudo-isochromatic screening before official medical admission exams.
Plate #14Aviation Pilot PAPI / Signal-Light & Ishihara Color Vision Check
Tests critical aviation red, green, and white signal discrimination alongside pseudo-isochromatic plates.
Plate #2Early Childhood & School-Age Color Vision Screening Plates
Gentle, instant browser screening to help parents spot classroom color-coding difficulties early.
Plate #4Electrician & Electronics Technician Color-Code Vision Screening
Verifies reliable distinction between brown, red, orange, green, and blue wiring insulation codes.
2. Calibrated Visual Acuity Tiers (20 Tests)
What Does 6/6 (20/20) Vision Mean? Interactive Calibrated Eye Test
Test whether your eyes resolve 1 arcminute of visual angle at calibrated screen distance.
Line 10 · 1.5m6/5 (20/16) Eagle Visual Acuity Test — Above-Average Sharpness
Challenge your foveal resolution beyond 20/20 using ISO Landolt C gap rings.
Line 11 · 2m6/4.5 (20/15) Fighter-Pilot Tier Visual Acuity Benchmark
Maximum clinical Snellen chart line testing 0.75-arcminute minimum angle of resolution.
Line 7 · 1m6/9 (20/30) Vision Explained & Interactive Distance Check
Understand 6/9 visual acuity—seeing at 6 meters what a 6/6 eye reads from 9 meters.
Line 6 · 1m6/12 (20/40) Driving License Eye Test Standard — Practice Online
Check the universal 6/12 (20/40) visual acuity threshold required by traffic authorities worldwide.
Line 4 · 1m6/18 (20/60) Acuity Tier — Classroom & Subtitle Legibility Check
Interactive optotype simulation of 6/18 distance acuity (Decimal 0.33, LogMAR 0.48).
Line 3 · 1m6/24 (20/80) Visual Acuity — Refractive Blur Screening
Evaluates larger optotype recognition when smaller Snellen rows appear blurred.
Line 2 · 1m6/36 (20/120) Acuity Reference & Calibration Line #2
Second largest Snellen calibration tier (Decimal 0.17).
Line 1 · 1m6/60 (20/200) Top Snellen E Letter — Exact Millimeter Size
Calculates and displays the exact giant top E optotype scaled for your distance.
Line 6 · 1mTumbling E Directional Eye Chart (Up / Down / Left / Right)
Language-independent directional E chart used across clinics, schools, and traffic departments.
Line 8 · 1mLandolt C Broken-Ring Eye Test (ISO 8596 Laboratory Standard)
Gold-standard scientific optotype eliminating letter-guessing bias.
Line 9 · 0.4m40 cm Near-Vision Reading Check (Age 40+ Presbyopia Screening)
Calibrated specifically for 40 cm smartphone/book reading distance to check near focus.
Line 9 · 0.7m70 cm Arm’s-Length Desktop Monitor Visual Acuity Check
Designed for sitting right at your desk (70 cm) without stepping across the room.
Line 9 · 2m2-Meter Step-Back Distance Visual Acuity Screening
Stepping back 2 meters relaxes eye accommodation for a truer distance myopia check.
Line 9 · 3m3-Meter (10-Foot) Clinical Half-Distance Eye Chart
Standard 3-meter clinical examination lane geometry.
Line 7 · 1mKids & School Entry Tumbling-E Vision Check (Ages 5+)
Child-friendly 4-arrow game letting kids point which way the table legs face.
Line 8 · 1mRight Eye (OD) vs. Left Eye (OS) Monocular Comparison Check
Compare each eye separately to spot subtle unilateral blur masked during two-eyed viewing.
Line 9 · 1.5mAre My Current Glasses Still 20/20? Wearing-Spectacles Check
Test your sharpness while wearing your current glasses or contact lenses.
Line 9 · 1mLogMAR, Snellen (6/6 & 20/20) & Decimal Acuity Interactive Table
Convert seamlessly between European decimal, UK metric 6m, US 20ft, and research LogMAR scores.
Line 8 · 1.5mNight Driving Blur & Pupil-Dilation Acuity Check
Why borderline daytime 6/9 blur worsens at night when pupils dilate.
3. Astigmatism, Contrast & Amsler Checks (16 Tests)
Astigmatism Sunburst & Clock-Dial Test — 360° Meridian Check
Check whether all 12 radial clock lines appear equally dark and sharp with one eye covered.
FAN180° With-the-Rule Astigmatism — Vertical vs Horizontal Line Blur
Explains why 12–6 o’clock vs 3–9 o’clock spokes look darker in common 180° astigmatism.
FAN90° Against-the-Rule Astigmatism Meridian Check
Screens horizontal vs vertical focal meridian asymmetry common in mature eyes.
FANOblique Astigmatism (45° & 135° Diagonal Axis) Screening Dial
Tests diagonal 1–7 and 2–8 vs 4–10 and 5–11 clock-dial spokes.
AMSLERInteractive Amsler Grid Test — Straight-Line Macular Field Check
Fixate on the central dot at 35 cm to verify all grid lines look straight, parallel, and complete.
AMSLERHigh-Visibility Inverted & Standard Clinical Amsler Grid
Standard 20×20 millimeter-proportioned macular screening grid.
CONTRASTVisual Contrast Sensitivity Test (100% Down to 1.25% Faint Gray)
Measures ability to distinguish faint gray optotypes against white—vital for fog and night driving.
CONTRASTFog, Dust & Dusk Driving Contrast Sensitivity Screening
Even with 6/6 high-contrast vision, reduced contrast sensitivity can impair low-visibility driving.
FANWhy Do Streetlights & Headlights Streak at Night? Astigmatism Check
Understand starburst headlight streaks and test radial spoke uniformity.
FANToric Astigmatism Contact Lens Sharpness & Rotation Check
Verify whether your toric lenses fully neutralize radial spoke differences.
CONTRAST1.25% Ultra-Faint Contrast Threshold Challenge (LogCS 1.90)
Tests peak human spatial contrast sensitivity on calibrated displays.
CONTRAST2.5% Fine Contrast Sensitivity Benchmark (LogCS 1.60)
Healthy young adult contrast threshold benchmark.
FANDigital Eye Strain & Uncorrected Mild Astigmatism Screening
Uncorrected 0.50D–0.75D astigmatism is a leading cause of afternoon screen headaches.
AMSLERWavy Text & Line Straightness Self-Check (Amsler Protocol)
Quick 30-second monocular straight-line grid verification.
CONTRASTPost-Refractive / Glasses Visual Crispness & Contrast Check
Evaluate both radial symmetry and subtle gray-level contrast.
FANCompare Right vs. Left Eye Astigmatism Axis Online
Most people have slightly different cylinder axes between right and left eyes—test each separately.
4. Farnsworth Hue & Color-IQ Benchmarks (16 Tests)
Online Hue Arrangement Test (Farnsworth D-15 / 100-Hue Style)
Sort subtle chromatic caps between fixed anchors to compute your Total Error Score (TES).
Band 2Graphic Designer & UI Artist Color IQ Discrimination Test
Benchmark your eye across emerald-cyan-teal micro-gradients and progressive odd-tile levels.
Band 3Odd Shade Out — 25-Level Progressive Color Threshold Grid
Spot the single tile with a shrinking ΔE chromatic difference before the timer runs out.
Band 1Warm Spectrum Hue Sort: Coral Rose to Olive Chartreuse
Tests fine L/M cone balance across warm skin-tone and golden-hour hues.
Band 2Cool-Green Spectrum Sort: Olive Sage to Cerulean Cyan
Challenges M-cone to S-cone transition perception across foliage and water hues.
Band 3Blue-Indigo Spectrum Sort: Cerulean to Periwinkle Violet
Tests short-wavelength S-cone tritan-axis discrimination.
Band 4Purple-Magenta Spectrum Sort: Orchid Violet to Dusty Rose
Evaluates non-spectral purple/magenta L+S cone ratios.
Band 1Dental & Cosmetic Shade-Matching Color Perception Check
Practice subtle warm ivory/hue discrimination required in aesthetic shade guides.
Band 2Print Press & Packaging Quality-Control Hue Test
Simulates industrial quality-assurance color tolerance sorting.
Band 3Jewelry & Gemstone Subtle Tint Discrimination Exercise
Train your visual cortex to spot 2-unit hue shifts.
Band 1Photographer Color-Cast & White-Balance Eye Calibration
Spot subtle magenta/green and warm/cool color casts effortlessly.
Band 3Automotive Paint & Interior Coating Color-Matcher Test
Essential hue-ordering practice for automotive refinishers and interior architects.
Band 4Textile & Fashion Dye-Lot Shade Sorting Challenge
Detect subtle dye-lot shifts across mauve, berry, and rose swatches.
Band 2Monitor Color Accuracy & Gradient Smoothness Visual Check
Verify both your monitor’s 8-bit sRGB separation and your own hue perception.
Band 4Superior Hue Discrimination Challenge — Can You Score TES = 0?
Attempt a flawless zero-transposition sort across all 10 chromatic caps.
Band 32-Minute Visual Chromatic Sensitivity Warm-Up before Color Grading
Calibrate your eyes on neutral D65 gray before editing photos or video.
5. Pure-Tone Hearing Frequency & Stereo Benchmarks (16 Tests)
How Old Are Your Ears? High-Frequency Hearing Test (8 kHz – 18 kHz)
Find your exact upper audible frequency in Hz and compare with ISO 7029 age benchmarks.
17400 Hz17,400 Hz Ultra-High Mosquito Tone Test — Under-20 Benchmark
Play a clean 17.4 kHz pure sine wave with click-free envelope ramping.
16000 Hz16,000 Hz (16 kHz) Pure-Tone Hearing & Headphone Bandwidth Check
Tests crisp 16 kHz air-band audibility.
15000 Hz15,000 Hz (15 kHz) Pure-Tone Audibility Benchmark (Under ~30)
Clean 15 kHz pure-tone check with Left/Right ear selector.
14000 Hz14,000 Hz (14 kHz) High-Treble Hearing Check (Under ~38)
Benchmarks healthy adult upper-octave sensitivity.
12000 Hz12,000 Hz (12 kHz) Hearing Frequency Check (Under ~50)
Verifies clear audibility in the 12 kHz brilliance band.
10000 Hz10,000 Hz (10 kHz) Treble Clarity & Earphone Driver Test
Standard 10 kHz high-treble pure tone audible across most adult age groups.
8000 Hz8,000 Hz (8 kHz) Clinical Audiogram Upper-Octave Tone
Top standard frequency tested on conventional clinical audiograms.
4000 Hz4,000 Hz (4 kHz) Loud-Music & Noise Sensitivity Tone Check
Tests the 4 kHz cochlear region most vulnerable to loud earbuds and concerts.
2000 Hz2,000 Hz (2 kHz) Speech Intelligibility & Consonant Band
Crucial frequency band for understanding speech clearly in restaurants and meetings.
1000 Hz1,000 Hz (1 kHz) Pure Sine Calibration Reference Tone
Universal acoustic calibration tone for setting a comfortable listening level first.
500 Hz500 Hz Low-Mid Pure Tone & Left/Right Ear Balance Check
Compare perceived loudness between your left and right ears at 500 Hz.
250 Hz250 Hz Bass Seal & Low-Frequency Tone Generator
Tests low-octave fullness and headphone cushion seal.
125 Hz125 Hz Deep Bass Pure-Tone Woofer & Ear Check
Smooth 125 Hz fundamental wave without harmonic distortion.
1000 HzLeft vs. Right Stereo Headphone & Ear Isolation Test
Verify correct L/R headphone wiring and compare left vs right ear clarity.
165 Hz165 Hz Low-Resonance Acoustic Sine Wave Generator
Generates a sustained 165 Hz acoustic excursion wave for speaker diaphragm testing.